Cig-Arrête smoke and flame detector systems

There are two types, the tobacco smoke detector and the match or lighter flame detector.

The tobacco smoke detector (CSA-GDV) is designed for the detection of cigarette smoke and drug residues in enclosed areas such as toilets, restrooms, bathrooms etc. Each unit will protect an area of approximately 27 cu m. (3m x 3m x 3m)

Click to see video

 

The match/lighter flame detector (CSA-FDV) will detect a 25mm flame at 6m within 1 second anywhere within its 120 degree field of view.

The detector is designed to work in areas subject to high winds or rapid ventilation areas etc. Typical applications include open areas, building entry/exit points, high ceiling rooms (>3m) or locations subject to intermittent smoke or vapour. Click to see video

 

A typical system consists of:

  • A master detector unit CSA-FDV (flame) or CSA-GDV (smoke);

  • A power supply (single battery, multiple battery or mains);

  • An output module to operate a remote warning device;

  • A remote warning beacon, either sound + strobe or strobe; and

  • Anti-vandal cages.

These systems are fairly complex, and require a knowledge of the individual components, for this reason we strongly advise that you contact us and we can give advice or design a system for you.

 

A standard Cig-Arrete Alarm Kit (CSA-KIT) is available or alternatively a system can be designed using the components below.

 

The systems can be powered by internal battery, however this is not advised if anti-vandal cages are used as the cage and detector must be de-mounted and re-mounted each time the battery is renewed. Much better to use an external battery box CSA-EBB which allows batteries to be replaced much easier. Alternatively external mains power can be used by either the CSA-SMPSU or the CSA-246.

 

For a typical installation of five detectors, a simple 8 core security type cable will be sufficient. Maximum cable length 250m.

 

NEW - Economy versions of the 'smoke' and 'flame detectors.

These are stand alone units that cannot be utilised as part of a larger integrated system, and cannot be powered by mains or remote batteries.

 

VEHICLE PROTECTION - PLEASE NOTE - the economy cigarette smoke detector (CSA-GDV/E) is not suitable for installation into motor vehicles, as they will detect even the very lightest engine emissions. The economy flame detector (CSA-FDV/E) is suitable for motor vehicles, as they will detect naked flames such as matches and lighters, however they will NOT detect vehicle electric cigarette type lighters.

  • Stand alone tobacco smoke detector and voice sounder CSA-GDV/E.

  • Stand alone flame detector and voice sounder CSA-FDV/E.

 

 

CSA-GDV/E

 

£99.00

 

The ECONOMY version of the stand alone tobacco smoke detector and voice sounder.

This unit is entirely 'STAND ALONE'. Unlike its counterpart the CSA-GDV it cannot be used as part of an integrated system, or powered by an external source.

 

The unit is battery powered, and is suitable for a single room or area such as a bed-sit.

NB if cooking facilities are within the room it is recommended that the CSA-FDV/E (flame detector) is used instead.

 

When cigarette smoke is detected one of two messages is broadcast at 92dB:

Message 1: "This is a no-smoking area, please extinguish your cigarette"

Message 2: "This is a no-smoking vehicle, please extinguish your cigarette

  • Simply fixed to the ceiling by 2-screws;

  • Coverage area approx 27 cubic m (3m x 3m x 3m);

It is recommended that this unit is protected by an CSA-AVC2 anti-vandal cage to prevent unauthorised tampering.

 

Back

 

CSA-FDV/E

 

£109.00

The ECONOMY version of the stand alone flame detector and voice sounder.

 

This unit is entirely 'STAND ALONE', it cannot be used as part of an integrated system, or powered by an external source. The unit is battery powered, and is suitable for a single room or area such as a bed-sit.

 

On detection of a lighter or match, the following message is broadcast:

"This is a no-smoking area, please extinguish your cigarette"

  • Can detect a 25mm match or lighter flame at 6m within 1 second (see coverage diagram below)

  • Provides clear voice message at up to 90dB (with volume control)

  • Powered by 1 x 9v PP3 alkaline battery;

  • 120 degree field of view;

  • Simply fixed to the ceiling by 2-screws.

 

It is recommended that this unit is protected by an CSA-AVC2 anti-vandal cage to prevent unauthorised tampering.

Back

 

CSA-GDV

 

£140.00

 

The Cig-Arrête master unit has an inbuilt tobacco smoke detector and voice sounder.

 

When cigarette smoke is detected one of two messages is broadcast at 92dB that can be repeated from 1 to 7 times:

Message 1: "This is a no-smoking area, please extinguish your cigarette, a member of staff has been contacted"

Message 2: "This is a no-smoking vehicle, please extinguish your cigarette"

  • Can be powered by internal batteries (1 x PP3 OR 4 x AA) or mains powered via a power supply unit;

  • Can be connected to external equipment using an additional daughter-board module (CSA-DBD);

  • Simply fixed to the ceiling by 2-screws;

  • Coverage area approx 27 cubic m (3m x 3m x 3m);

  • Anti-vandal cage AVC2 (optional) prevents unauthorised tampering with detector. NB! We strongly recommend the unit is powered externally if this is used as the cage AND sensor units must be de-mounted then re-mounted each time the battery needs replacing. Use either battery box CSA-EBB, Power Supply Unit CSA-246 or Power Supply CSA-SMPSU

Back

 

 

CSA-SGA

 

£80.00

 

The Cig-Arrête (Slave) Smoke Detector will protect an area of approximately 27 cubic m (3m x 3m x 3m). When installed as part of a Cig-Arrête Tobacco Control System, the SGA can be combined with Stand Alone Master units (CSA-FDV or CSA-GDV) to provide complete smoke/flame hybrid coverage. Supplied complete with base.
Anti-vandal cage AVC (optional) prevents unauthorised tampering with detector.

Back

 

 

CSA-GDT

 

£130.00

 

This self contained battery operated unit has an inbuilt tobacco smoke detector and tone sounder.

 

On detection of tobacco smoke, a warble tone is given for a user specified time.

  • Powered by 4 x AA or 1 x 9v PP3 alkaline battery;

  • Variable sensitivity.

  • Can be connected to external equipment using an additional daughter-board module (CSA-DBD);

  • Can be remotely powered at 6v-12v dc (when using an additional daughter-board module CSA-DBD);

  • Simply fixed to the ceiling by 2-screws;

  • Coverage area approx 3m x 3m x 3m.

  • Anti-vandal cage AVC2 (optional) prevents unauthorised tampering with detector. NB! We strongly recommend the unit is powered externally if this is used as the cage AND sensor units must be de-mounted then re-mounted each time the battery needs replacing. Use either battery box CSA-EBB, Power Supply Unit CSA-246 or Power Supply CSA-SMPSU

Back

 

CSA-FDV

 

£150.00

 

This self contained battery operated unit has an inbuilt flame detector and voice sounder.

 

On detection of a lighter or match, the following message is broadcast:

"This is a no-smoking area, please extinguish your cigarette, a member of staff has been contacted"

  • Can detect a 25mm match or lighter flame at 6m within 1 second (see coverage diagram below)

  • Provides clear voice message at up to 90dB (with volume control)

  • Powered by 1 x 9v PP3 alkaline battery;

  • 120 degree field of view;

  • Built in alarm relay for connection to remote equipment (contacts rated at 1A 24v dc);

  • Can be remotely powered using optional power supply CSA-SMPSU;

  • Simply fixed to the ceiling by 2-screws.

  • Anti-vandal cage AVC2 (optional) prevents unauthorised tampering with detector. NB! We strongly recommend the unit is powered externally if this is used as the cage AND sensor units must be de-mounted then re-mounted each time the battery needs replacing. Use either battery box CSA-EBB, Power Supply Unit CSA-246 or Power Supply CSA-SMPSU

NB! WEATHERPROOF version of this CSA-FDW

Back

 

 

CSA-FUV

 

£90.00

 

The Slave flame detector is used to extend the range of the master flame detector CSA-FDV, or in conjunction with a master smoke detector CSA-GDV.

Supplied complete with base.

Anti-vandal cage AVC (optional) prevents unauthorised tampering with detector.

 

NB! WEATHERPROOF version of this CSA-FDWS

Back

 

 

CSA-FDW

£180.00

 

 

Weatherproof flame detector - similar spec to CSA-FDV plus:

  • Tough, aesthetic, brilliant white GRP housing

  • Optional plug in relay for connection to remote equipment

  • Can be powered by single integral battery

  • Can also be powered by mains adaptor CSA-SMPSU  or  CSA-246. Can also be powered by 4 x D cell batteries in CSA-EBB battery box. (these all also need a daughter board CSA-DBD)

To extend the coverage use slave flame detector CSA-FDWS (below).

 

CSA-FDWS

£140.00

 

 

Weatherproof SLAVE flame detector - similar to CSA-FUV (above).

Designed to be linked to a CSA-FDW (above) to extend the coverage, see chart below for coverage of all flame detector units. Requires a daughter board CSA-DBD and power supply CSA-SMPSU  or  CSA-246. Can also be powered by 4 x D cell batteries in CSA-EBB battery box

 

 

 

 

 

 

Coverage

diagram

for flame

detectors

 

 

 

 

X = 1 

X = 2 

X = 3 

X = 4 

X = 5

X = 6 

Y = 3.5

Y = 7

Y = 10

Y = 14

Y = 17

Y = 21

CSA-KIT

 

£350.00

 

 

The Cig-Arrete Alarm Kit is a complete kit to ensure your premises are protected.

The kit comprises:

  • 1 x Cig-Arrête Standard Controller (CSA-S5B)

  • 3 x Cig-Arrête Sensor Units (CSA-SGA)

  • 1 x Anti Tamper Screwdriver (CSA-ATS)

  • 1 x Detector Test Gas (CSA-DTG)

 

Click here to see a typical layout

Back

 

 

CSA-S5B

 

£135.00

 

 

At the heart of the Cig-Arrête alarm system, the standard controller performs all the functionality to ensure your system operates efficiently. The controller is supplied with a mounting bracket.

Capable of driving up to 5  Cig-Arrête sensors (one zone per detector) it provides a visual indication of fault & alarm conditions at a remote location,. Audible confirmation is facilitated by means of the integral buzzer which provides a beep at each event.

The controller may be battery operated using 4 x D type cells. Alternatively, an auxiliary power supply (CSA-246 / CSA-PSU) may be used. (110v units are also available)

Back

 

 

CSA-S5BAR

 

£135.00

 

 

Similar to the CSA-S5B above, but automatically resets after 30 seconds.

 

Back

 

 

 

CSA-246

 

£79.00

 

 

240v ac / 24v dc / 6v dc Power Supply Unit designed to operate all the range of Cig-Arrête Ant-Smoking products. Each unit provides sufficient power for 3 Standard Control Units (CSA-S5B or CSA-S5BAR) and an alarm device (CSA-XBN or CSA-CSB).

 

Back

 

CSA-EBB

£20.00

 

Battery Box

Takes 4 x D cell batteries. Has the advantage of being able to change batteries remotely, and has an extended life over single batteries.

Back

 

CSA-SMPSU

 

£35.00

 

The Cig-Arrête Power Supply operates direct from 240v mains supply (UK only). 6v DC 1amp power supply for stand alone products

Back

 

 

CSA-DBD

 

£30.00

This module is designed only for use with the Cig-Arrete Stand Alone Module (CSA-GDV/GDT/FDV/FDW). The module allows connection to external equipment via a volt free contact. In addition it allows the CSA-GDV to be locally powered, or be connected to a Cig-Arrête Controller Unit

Back

 

 

CSA-RAI

 

£25.00

 

Remote alarm signalling.

6V remote sounder. The Cig-Arrête Remoter Alarm Indicator is designed to work direct from the auxiliary output of the controller, and provides a high output tone (88dBA at 1m) for remote signalling.

Back

 

 

CSA-RA124

 

£25.00

 

Alarm signalling in NOISY AREAS.

The Cig-Arrête Remoter Alarm Indicator is designed to operate only on conjunction with Cig-Arrête power supplies CSA-246 or CSA110, and provides a high output tone (96dBA at 1m) for signalling in noisy areas.

 

Back

 

CSA-VAS

 

£110.00

 

Voice alarm

Pre-recorded voice messages allow a message to be broadcast to staff or the protected area. The message will repeat until the 'Silence' button is pressed on the controller. <Alert Tone> "This is a no-smoking area, please extinguish your cigarette, a member of staff has been contacted" <Alert Tone>

Back

 

 

CSA-CSB

 

£50.00

 

The Cig-Arrête Combined Sounder Beacon provides both audible and visual indication of an alarm.

The unit is powered by the CSA-246 power supply unit.

Back

 

 

CSA-XBN

 

£30.00

 

The Cig-Arrête Xenon Beacon provides a visual alarm.

The unit is powered by the CSA-246 power supply unit.

 

Back

 

CSA-AVC

 

£25.00

 

This Anti Vandal Cage offers a high degree of protection to each SLAVE sensor unit in areas likely to be subject to wilful damage or vandalism.

(NB! the CSA-AVC2 below must be used for the stand alone MASTER sensors as it is deeper than the CSA-AVC).

  • Made from high grade steel;

  • Fully welded joints providing a robust cage structure;

  • Powder coated for long life;

  • Can be fitted at same time as sensors, or retrofitted later.

 

Back

 

CSA-AVC2

 

£30.00

 

This Cig-Arrete Anti Vandal Cage offers protection to MASTER SENSORS and SOUNDER BEACONS in areas likely to be subject to wilful damage or vandalism.

 

  • Made from high grade steel;

  • Fully welded joints providing a robust cage structure;

  • powder coated for long life;

  • Can be fitted at same time as sensors, or retrofitted later.

Back

 

 

 

 

CSA-VFR

 

£30.00

 

 

This Cig-Arrête volt free relay card provides an interface from the normal 6v dc / 3 mA aux power output of the Cig-Arrête controller (CSA-S5B or CSA-S5BAR).

This unit is capable of switching loads of up to 1 Amp but is an extremely low current solid state device. Typical uses include the provision of a volt free (clean) contact for analogue addressable fire alarm systems, security alarms, building management systems, heating and ventilation systems, CCTV operations, paging systems and GSM modem signalling to outside equipment.

Back

 

CSA-ATS

 

£8.00

 

The Cig-Arrete Anti-Tamper Screwdriver is a special screwdriver providing the means to lock each Sensor Unit in its own base.

Intended to prevent smokers tampering with sensors or removing them.

 

Back

 

CSA-DCB

 

£8.00

 

The Cig-Arrête Sensor Conduit Base provides a means of installing the Sensor Unit (CSA-SGA) to a concrete ceiling. The conduit base has both 16mm and 20mm entries for plastic conduit.

The base is also ideal for providing a backstop for sandwiching tiles between the base and sensor when installing under a suspended ceiling.

 

Back

 

CSA-SGTG

£17.50

Test Gas

Clean and hygienic, this test gas allows you to test the system without the need to light a cigarette.

Back

 

 

No Smoking Label

 

£5.00

Self-adhesive laminated No Smoking label to add an extra deterrent to smokers.

Fixes simply and easily to doors, walls and windows etc.

Pack of 5 labels 100mm x 75mm.

 

Back

Prices plus delivery and VAT

 

Back

 

Payment by pro-forma invoice or credit card

Home
Confined Spaces
Consultancy
Construction Sites
Disabled Evacuation
Dorgard
Fire Engineering
Firs Safety Equipment
Fire Sprinklers
Fire Legislation
Fire Strategies
Fire Training Videos
H & S Videos
Home Safety
Hospitals
Hotels
Residential Care
Risk Assessment
Training
What Now???
Contact us
Useful Contacts
References
Site Map

 

 

 

e-mail info@marsden-fire-safety.co.uk    Tel : 0845 644 6515 or 01282 691616

Confined Spaces ] Consultancy ] Construction Sites ] Disabled Evacuation ] Dorgard ] Fire Engineering ] Firs Safety Equipment ] Fire Sprinklers ] Fire Legislation ] Fire Strategies ] Fire Training Videos ] H & S Videos ] Home Safety ] Hospitals ] Hotels ] Residential Care ] Risk Assessment ] Training ] What Now??? ] Contact us ] Useful Contacts ] References ] Site Map ]